Temperature Function:
1>. Automatic recognition of working mode:
The module automatically selects the working mode according to the Start Temperature and Stop Temperature.
Start Temperature is more than stop temperature, Turn ON cooling mode 'C'.
Start temperature is less than stop temperature, Turn ON heating mode 'H'.
2>. Cooling Mode 'C':
Relay turn ON and Red Indicator turn ON and Refrigeration equipment starts working if connect load when Current Temperature is more than Start Temperature.
Relay turn OFF and Red Indicator turn OFF and Refrigeration equipment stops working if connect load when Current Temperature is less than Stop Temperature.
3>. Heating mode 'H':
Relay turn ON and Red Indicator turn ON and Heating equipment starts working if connect load when Current Temperature is less than Start Temperature.
Relay turn OFF and Red Indicator turn OFF and Heating equipment stops working if connect load when Current Temperature is more than Stop Temperature.
4>. Temperature Correction ‘ OFE ’(-10.0~10.0℃):
The system may have errors if it works for a long time, it can be corrected by this function.
Actual Temperature = Measured Temperature + Calibration Value.
Setting method:
4.1>.Double-click button 'TM+' in the normal running interface into Temperature Correction setting interface.The first line shows the type of correction value(OFE or RH).The second line shows the specific value.
4.2>.Switch to select modified parameters by short press button ‘TM-’.
4.3>.Short press button ‘RH+’ and ‘RH-’ to set the specific value.Support long press.
4.4>.After the parameters have been modified, double-click button ‘TM+’ to save the data and exit the correction value setting interface.
5>. Set Start/Stop Temperature:
Keep press button 'TM+' for 3second in the normal running interface into Start Temperature setting interface.Short press button 'TM+' or 'TM-' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.
Keep press button 'TM-' for 3second in the normal running interface into Stop Temperature setting interface.Short press button 'TM+' or 'TM-' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.
6>. Relay enable (default on):
Short press button ‘TM-’ in the normal running interface.Turn ON or OFF temperature relay output enable.Screen will display ‘℃’ and flashes if If the temperature relay is OFF.

Humidity Function:
1>. Automatic recognition of working mode:
The module automatically selects the working mode according to the Start Humidity and Stop Humidity.
Start Humidity is more than stop Humidity, Turn ON dehumidification mode 'd'.
Start Humidity is less than stop Humidity, Turn ON humidification mode 'E'.
2>. Dehumidification Mode 'd':
Relay turn ON and Green Indicator turn ON and Dehumidification equipment starts working if connect load when Current Humidity is more than Start Humidity.
Relay turn OFF and RED Indicator turn OFF and Dehumidification equipment stops working if connect load when Current Humidity is less than Stop Humidity.
3>. Humidification mode 'E':
Relay turn ON and Green Indicator turn ON and Humidification equipment starts working if connect load when Current Humidity is less than Start Humidity.
Relay turn OFF and Green Indicator turn OFF and Humidification equipment stops working if connect load when Current Humidity is more than Stop Humidity.
4>.Humidity Correction ‘ RH ’(-10.0~10.0%RH):
The system may have errors if it works for a long time, it can be corrected by this function.
Actual Humidity= Measured Humidity+ Calibration Value.
4.1>.Double-click button 'TM+' in the normal running interface into Temperature Correction setting interface.The first line shows the type of correction value(OFE or RH).The second line shows the specific value.
4.2>.Switch to select modified parameters by short press button ‘TM-’.
4.3>.Short press button ‘RH+’ and ‘RH-’ to set the specific value.Support long press.
4.4>.After the parameters have been modified, double-click button ‘TM+’ to save the data and exit the correction value setting interface.
5>.Set Start/Stop Humidity:
Keep press button 'RH+' for 3second in the normal running interface into Start Humidity setting interface.Short press button 'RH+' or 'RH-' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.
Keep press button 'RH-' for 3second in the normal running interface into Stop Humidity setting interface.Short press button 'RH+' or 'RH-' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.
6>.Relay enable (default on):
Short press button ‘RH-’ in the normal running interface.Turn ON or OFF humidity relay output enable.Screen will display ‘%’ and flashes if If the temperature relay is OFF.

Using Steps:
1>. Connect sensor to controller;
2>. Connect to power supply to controller;
3>. Adjust Start Temperature, Stop temperature and Temperature Correction;
4>. Adjust Start Humidity, Stop Humidity and Humidity Correction;
5>. Enable relay output according requirement;
6>. Remove power supply;
7>. Connect to load with power supply at relay output terminal if need at Step5;
8>. Connect to power supply for controller again;
9>. Test and working!

Additional Features:
1>. Set or read data by UART.
Parameters such as start temperature/humidity, stop temperature/humidity, temperature/humidity correction, etc. can be set through the UART.
2>. Temperature/Humidity real-time reporting.
The controller module will report the current temperature/humidity to the terminal equipment by the UART at intervals of 1 second to facilitate data acquisition if the temperature/humidity reporting function is turned ON.
3>. Relay enable (default on).
If the relay enable is turned off, the relay remains off.
That is, the output state will never change, no matter what the measured temperature/humidity is.


UART Communication and Parameter Settings:
The system supports UART data upload and parameter setting functions (TTL level);
UART: 9600, 8, 1

NO.CommandFunction
1StartStart test value report
2StopStop test value report
3ReadRead setting parameters
4T:ONTemperature Relay enable ON
5T:OFFTemperature Relay enable OFF
6H:ONHumidity Relay enable ON
7H:OFFHumidity Relay enable OFF
8TS:XX.XSet Start Temperature Value (-20.0~60.0℃)
9TP:XX.XSet Stop Temperature Value (-20.0~60.0℃)
10HS:XX.XSet Start Humidity Value (00.0%~100.0%RH)
11HP:XX.XSet Stop Humidity Value (00.0%~100.0%RH)
12TC:XX.XTemperature calibration (-10.0~10.0℃)
13HC:XX.XHumidity calibration (-10.0~10.0%RH)

Temperature and humidity data upload format:
Temperature format: work mode (H/C), Current Temperature, Temperature relay status;
Humidity format: work mode (E/D), Current Humidity, Humidity relay status;
For example:
H, 20.5℃, CL: Heating Mode, Current Temperature 20.5℃, Temperature relay is OFF.
D, 50.4%,OP: Dehumidification mode, Current Humidity 50.4%RH, Humidity relay is ON.


نظر خود را بنویسید
*
*
19
دیدگاه کاربران
  • 1398-06-26

    سلام
    من این ماژول را گرفتم کیفیتش عالیه، جنس رله ها خوب بودند. وجود نمایشگر oled روی این ماژول خیلی کاربردیه سنسورش هم داخل گلخانه قرار دادم که بسیار عالی داره کار میکنه
    ممنونم از دانشجو کیت با اجناس با کیفیتشون

    پاسخ مدیر:

    با سلام


    از توجه شما سپاسگزاریم.

    پاسخ کاربر: مهدی احسانی 1399-04-22

    سلام آقای صباغی آیا این ماژول برای گلخانه جواب میده واقعا
    دما رو دقیق میگه؟ اشتباه نمیگه؟
    میشه مثلا تنظیمش کرد که اگر دما از ۲۴ درجه بالاتر رفت فن روشن بشه یا پایین اومد هیتر روشن بشه؟
    و این که گلخانه ی شما چند متر مربع هست؟
    از من حدود به ۱۵۰ متره که اگر جواب بگیرم میخوام گلخانه ۲۰۰۰ متری راه بندازم و از همین ماژول استفاده کنم ولی خب خروجیه رله هارو به کنتراکتور میدم
    حرف کلیه من اینه آیا دما رو دقیق نشون میده و سر موعود خروجی به رله ها میده یا نه
    چیز به درد بخوری هست یا نه
    خودتون میدونین گلخانه شوخی بردار نیست یه ذره اختلاف دما محصول رو خراب میکنه!
    ممنون میشم راهنمایی کنید

  • 1398-07-29

    سلام
    لطف کنیدروش استفاده و راه اندازی این ماژول و روش استفاده از خروجیهای رله ها و کاربرد انها را لینک کنید یا در قسمت نظرات یا اطلاعات بگذارید

    پاسخ مدیر:

    با سلام


    آموزش راه اندازی این کالا فقط برای کاربرانی که خریداری کرده‌اند در دسترس می‌باشد. چنانچه جنابعالی این کالا را خریداری کرده‌اید، می‌توانید از طریق پرتال پشتیبانی و بخش راهنمایی کار با محصولات، درخواستتان را ارسال بفرمایید.

  • 1398-09-05

    با عرض سلام اگه ممکنه اندازه طول و عرض خود برد رو لحاظ کنید مرسی

    پاسخ مدیر:

    با سلام


    ضمن تشکر از توجه شما، به درخواست شما، اطلاعات این کالا به روزرسانی شدند.

  • 1398-09-05

    با عرض سلام اگه ممکنه اندازه طول و عرض خود برد رو لحاظ کنید مرسی

    پاسخ مدیر:

    با سلام


    کاربر گرامی ابعاد این کالا در تصاویر کالا لحاظ شده است.

  • 1398-09-23

    دوستانی که این ماژول را خریده اند یا از دست اندرکاران خود دانشجوکیت تقاضا دارم که مقادیر اولیه برای کالیبره که روی خود برد به صورت پیشفرض قرار دارد رو اینجا در جواب بنویسند در صورت امکان بسیار از شما متشکر خواهم بود...
    بنده متاسفانه مقدار اولیه را به هم زدم و الان مقادیر اولیه را نمیدانم...

    پاسخ مدیر:

    با سلام


    از توجه شما سپاسگزاریم. در صورتی که این کالا را از دانشجو کیت تهیه کرده‌اید، میتوانید از طریق پرتال پشتیبانی و بخش راهنمایی کار با محصول، درخواستتان را پیگیری بفرمایید.

  • 1398-10-04

    سلام. این کیت برای بنده که هیچ تخصصی در الکترونیک ندارم هم قابل استفادست؟

    پاسخ مدیر:

    با سلام


    بله دارای فایل راهنما میباشد. همچنین پس از خرید میتوانید از طریق پرتال پشتیبانی پیگیری بفرمایید.

  • 1398-10-07

    سلام آیاامکان سفارش دادن این کیت با سنسور ضد آبDS18B20هست؟اگر هست رنج کاری کیت تغییر میکند یا نه؟

    پاسخ مدیر:

    با سلام


    خیر، این برد به همراه سنسور همراه خودش کارایی دارد و امکان جابجایی سنسور وجود ندارد.

  • 1398-10-09

    عرض سلام مجدد
    دو سوال دارم ازتون
    1-برای کنترل دما قابلیت اتصال و کنترل همزمان هیتر و کولر رو داره؟
    2-برای کنترل رطوبت قابلیت اتصال و کنترل همزمان رطوبت ساز و فن رو داره؟

    پاسخ مدیر:

    با سلام


    1- بخش دمایی این ماژول یک رله دارد و فقط امکان فرمان به یک وسیله برقی فراهم خواهد بود.


    2- در خصوص کنترل رطوبت هم به همین صورت میباشد.

  • 1398-10-12

    برای این کنترلر میشه از اداپتور ۱۲ یک امپر استفاده کرد

    پاسخ مدیر:

    با سلام


    طبق اطلاعات ارایه شده از طرف تولید کننده از 6 تا 30 ولت قابلیت اتصال به بخش ورودی دارد. ولی این موضوع توسط دانشجو کیت تست نشده است.

  • 1398-10-12

    سلام این برد برای دستگاه جوجه کشی هم مناسب هست یا خیر ورله خروجی فن دارد یا...

    پاسخ مدیر:

    با سلام


    بله مناسب می‌باشد، این ماژول دارای یک خروجی رله برای کنترل رطوبت و یک خروجی رله برای کنترل دما میباشد.

صفحه نمایش

نوع نمایشگر : OLED

تغذیه

ولتاژ مورد نياز : 12 ولت

ویژگی های فنی

دمای کاری : - 20 تا + 60 درجه سانتی گراد
کد تجاری ماژول و برد : XY-TR01

سایر مشخصات کالا

سطح تجربه مورد نیاز : حرفه ای
نوع کاربرد محصول : مناسب برای استفاده صنعتی
نوع برد - ماژول : دماسنج - Thermometer
سنسور : SHT20
خروجی : دارای خروجی رله
سایر توضیحات : رنج اندازه‌گیری رطوبت: 0%-100%RH
سایر قابلیت‌ها : دارای دو رله
بنچ مارک تیم فنی دانشجو کیت : 9 از 10

محصولات مرتبط

نورپردازی با LED RGB و برد آردوینو با پتانسیومتر و نمایش LCD کاراکتری